Dranetz Visa User's Guide Page 234

  • Download
  • Add to my manuals
  • Print
  • Page
    / 274
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 233
E-10
3 Phase (Floating or Grounded) Delta
3 Phase (Floating or Grounded) Delta
Introduction
In this power connection, the PowerVisa uses voltage channels A, B, and C as
differential inputs with channel A using source voltage A-B, channel B using B-C, and
channel C using C-A as the reference. Current probes are connected to channels A, B,
and C. Neutral to ground measurements are important but optional.
Connection
diagram
Floating Delta
phasor diagrams
PX5-904
V
A
V
B
120º
V
C
240º
I
A
I
C
330º
90º
I
B
210º
Page view 233